Title: PERSON DEPENDENT AND INDEPENDENT THERMO HYGROMETRIC COMFORT SENSORS: STUDY, DESIGN, BUILDING, CALIBRATION AND TESTS
Authors: Coppa, Paolo
Malvicino, Carlo Andrea
Pezzotti, Gianni
Keywords: Thermo Hygrometric Comfort
Sensor Design
Pyrometer
Flat Sensors
PMV
Issue Date: 15-Dec-2005
Abstract: This thesis presents results about the design and the implementation of sensors to measure variables governing thermal comfort or thermal sensation. Two different kinds of devices have been developed: one is the dependent and the other one is the independent sensor. The sensor of dependent comfort is a low temperature pyrometer, consisting of an optical system, a mechanical support and a radiation sensor. The instrument is attached to the rear view mirror for detecting the comfort level by the forehead temperature of a passenger living in the compartment. The sensor of independent comfort is a single instrument able to measure, during the same test, three of the four quantities which have major influence on the comfort sensation: air temperature, mean radiant temperature and air velocity. The device, built at the Microsensors Laboratory of CNR (“Tor Vergata” Research Area), has small size (50mm x 50mm) and is divided in two halves: a blackened one and a bright one. The sensib...
URI: http://hdl.handle.net/2108/178
Appears in Collections:Tesi di dottorato in ingegneria

Files in This Item:

File Description SizeFormat
PERSON DEPENDENT AND INDEPENDENT THERMO HYGROMETRIC COMFORT .pdf2485KbAdobe PDFView/Open

Show full item record

All items in DSpace are protected by copyright, with all rights reserved.